| Metalized |
|
|
|
| Product Description |
M-PE Standard is highly effective insulator, which is produced by modern technology of coating Metalized Film with Non-crosslinked Polyethylene Foam having Thermal Conductivity of 0.029 W/mk. (ASTM C-177). Lamination the surface with Plastic Film (Polyethylene Terehthalate) by Dry Lamination Process increases scratch consistent to the surface, as well as weather and moisture resistance. |
| |
| Type of heat protection |

|
M-PE Standard has Double Heat Protection, which is able to reflect heat emission and protect
heat transmission. Due to its structure of closed cell, M-PE shall not induce heat, prevent moisture condensation and weather durability. Moreover, M-PE Standard is able to transmit voice well and also has neutral qualification that helps the insulator consist from acid and base. M-PE Standard contains FR and can protect ultraviolet (UV). This type of insulator has long life using more than 10 years.
|
|
| Material for laminated surface |
M-PE Standard is laminated the surface with Matalized Film, which has the qualification of 86.33% (JIS R3106) heat reflectivity, only 0.14 heat radiation and strong surface resistance. |
| |
| The structure of M-PE Standard Insulator |
1. Plastic Film
2. Aluminium Base Film
3. Special Adhesive
4. Plastic Film
5. Polyethylene Insulator
|
| |
| Product Utility |
M-PE Standard has high elastic structure so that it can be installed easily with all types of construction such as roof, ceiling and wall that can assist time and budget saving. In addition, M-PE Standard does not irritate skin and respiratory system and also protect germ or insect. |
|
Physical Property Data of M-PE Standard
|
| Reflectivity |
JIS R3106 |
|
| Emissivity |
- |
0.14 |
Thermal Conductivity
|
|
|
| Water Absorption |
|
|
| Surface Resistant |
ASTM-D267 |
|
| Surface Gloss |
JIS K6714
|
770% |
|
| |
ค่าการต้านทานการส่งผ่านความร้อน
|
| M-PE |
Unit |
5 mm. |
10 mm. |
| R-Value |
m2.k./W |
1.92 |
2.09 |
hr.ft2 .°f/Btu |
11 |
12 |
|
| |
Reduction of heat transmission at 65 °c
|
| M-PE |
Unit |
5 mm. |
10 mm. |
| R-Value |
|
|
|
|
| |
Reduction of heat transmission after insulator installation
|
| M-PE |
Unit |
5 mm. |
10 mm. |
| R-Value |
% |
67 |
70 |
|
| |
Standard size for ceiling (Pack)
|
| M-PE |
|
|
| 5 mm. |
60 x 60 ซม. |
0.90 x 8 ม. |
| 10 mm. |
60 x 60 ซม. |
0.90 x 4 ม. |
|
| |
Standard Size for construction project (Roll) |
| Thickness |
Width (m.) |
Length (m.) |
| |
0.90 |
1.00 |
25 |
50 |
100 |
| 3 |
x |
|
|
x |
x |
| 4 |
x |
|
|
x |
x |
| 5 |
x |
|
|
x |
x |
| 10 |
x |
x |
x |
x |
|
| 15 |
x |
x |
x |
|
|
| 20 |
x |
x |
x |
|
|
|